  "url": "https://openlegislation.uk/eu-decision-2012-134/annex/division-5/division-1.1/division-1.1.4/division-7",
  "json_url": "https://openlegislation.uk/eu-decision-2012-134/annex/division-5/division-1.1/division-1.1.4/division-7.json",
  "legislation": "eudn/2012/134",
  "legislation_title": "Commission Implementing Decision of 28 February 2012 establishing the best available techniques (BAT) conclusions under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions for the manufacture of glass (notified under document C(2012) 865) (Text with EEA relevance) (2012/134/EU)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2012-134",
  "path": "annex/division/5/division/1.1/division/1.1.4/division/7",
  "kind": "division",
  "number": "7",
  "heading": null,
  "text": "BAT is to carry out monitoring of emissions and/or other relevant process parameters on a regular basis, including the following:\nTechnique\nApplicability\n(i)\nContinuous monitoring of critical process parameters to ensure process stability, e.g. temperature, fuel feed and airflow\nThe techniques are generally applicable\n(ii)\nRegular monitoring of process parameters to prevent/reduce pollution, e.g. O2 content of the combustion gases to control the fuel/air ratio.\n(iii)\nContinuous measurements of dust, NOX and SO2 emissions or discontinuous measurements at least twice per year, associated with the control of surrogate parameters to ensure that the treatment system is working properly between measurements\n(iv)\nContinuous or regular periodic measurements of NH3 emissions, when selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) techniques are applied\nThe techniques are generally applicable\n(v)\nContinuous or regular periodic measurements of CO emissions when primary techniques or chemical reduction by fuel techniques are applied for NOX emissions reductions or partial combustion may occur.\n(vi)\nRegular periodic measurements of emissions of HCl, HF, CO and metals, in particular when raw materials containing such substances are used or partial combustion may occur\nThe techniques are generally applicable\n(vii)\nContinuous monitoring of surrogate parameters to ensure that the waste gas treatment system is working properly and that the emission levels are maintained between discontinuous measurements. The monitoring of surrogate parameters includes: reagent feed, temperature, water feed, voltage, dust removal, fan speed, etc.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2012/134/annex/division/5/division/1.1/division/1.1.4/division/7",
    "retrieved_at": "2026-11-01T15:15:31.348652+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}