# Commission Implementing Decision of 28 February 2012 establishing the best available techniques (BAT) conclusions under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions for the manufacture of glass (notified under document C(2012) 865) (Text with EEA relevance) (2012/134/EU), Division 16

Extent: E+W+S+N.I.

BAT is to reduce dust emissions from the waste gases of the melting furnace by applying a flue-gas cleaning system such as an electrostatic precipitator or a bag filter.
A description of filtration systems (i.e. electrostatic precipitator, bag filter) is given in Section 1.10.1.
Technique
Applicability
The flue-gas cleaning systems consist of end-of-pipe techniques based on the filtration of all materials that are solid at the point of measurement
The technique is generally applicable
Table 6
BAT-AELs for dust emissions from the melting furnace in the container glass sector
The conversion factors of 1,5 × 10–3 and 3 × 10–3 have been used for the determination of the lower and higher value of the range respectively.
Parameter
BAT-AEL
mg/Nm3
kg/tonne melted glass
Dust
< 10 – 20
< 0,015 – 0,06

---
Source: https://www.legislation.gov.uk/eudn/2012/134/annex/division/5/division/1.2/division/1.2.1/division/16 (the official version)