Division 20
United Kingdom
BAT is to reduce HCl and HF emissions from the melting furnace (possibly combined with flue-gases from hot-end coating activities) by using one or a combination of the following techniques:
| A description of the techniques is given in Section 1.10.4. | |
| Techniquef1 | Applicability |
|---|---|
| (i) Selection of raw materials for the batch formulation with a low content of chlorine and fluorine | The applicability may be limited by the constraints of the type of glass produced at the installation and the availability of raw materials |
| (ii) Dry or semi-dry scrubbing, in combination with a filtration system | The technique is generally applicable |
Table 10
BAT-AELs for HCl and HF emissions from the melting furnace in the container glass sector
| The conversion factor for general cases, reported in Table 2 (1,5 × 10–3) has been applied. | ||
| The higher levels are associated with the simultaneous treatment of flue-gases from hot-end coating operations. | ||
| Parameter | BAT-AEL | |
|---|---|---|
| mg/Nm3 | kg/tonne melted glassf2 | |
| Hydrogen chloride, expressed as HClf3 | < 10 – 20 | < 0,02 – 0,03 |
| Hydrogen fluoride, expressed as HF | < 1 – 5 | < 0,001 – 0,008 |
Annotations
Footnotes
- f1
-
A description of the techniques is given in Section 1.10.4.
- f2
-
The conversion factor for general cases, reported in Table 2 (1,5 × 10–3) has been applied.
- f3
-
The higher levels are associated with the simultaneous treatment of flue-gases from hot-end coating operations.