Division 29
United Kingdom
BAT is to reduce metal emissions from the melting furnace by using one or a combination of the following techniques:
| A description of the techniques is given in Section 1.10.5. | |
| Techniquef1 | Applicability |
|---|---|
| (i) Selection of raw materials for the batch formulation with a low content of metals | The applicability may be limited by the constraints imposed by the type of glass produced at the installation and the availability of the raw materials. |
| (ii) Applying a filtration system | The technique is generally applicable |
| (iii) Applying a dry or semi-dry scrubbing, in combination with a filtration system | |
Table 19
BAT-AELs for metal emissions from the melting furnace in the flat glass sector, with the exception of selenium coloured glasses
| The ranges refer to the sum of metals present in the flue-gases in both solid and gaseous phases. | ||
| The conversion factor reported in Table 2 (2,5 × 10–3) has been applied | ||
| Parameter | BAT-AELf2 | |
|---|---|---|
| mg/Nm3 | kg/tonne melted glassf3 | |
| Σ (As, Co, Ni, Cd, Se, CrVI) | < 0,2 – 1 | < 0,5 – 2,5 × 10–3 |
| Σ (As, Co, Ni, Cd, Se, CrVI, Sb, Pb, CrIII, Cu, Mn, V, Sn) | < 1 – 5 | < 2,5 – 12,5 × 10–3 |
Annotations
Footnotes
- f1
-
A description of the techniques is given in Section 1.10.5.
- f2
-
The ranges refer to the sum of metals present in the flue-gases in both solid and gaseous phases.
- f3
-