  "url": "https://openlegislation.uk/eu-decision-2012-134/annex/division-5/division-1.6/division-1.6.2/division-50",
  "json_url": "https://openlegislation.uk/eu-decision-2012-134/annex/division-5/division-1.6/division-1.6.2/division-50.json",
  "legislation": "eudn/2012/134",
  "legislation_title": "Commission Implementing Decision of 28 February 2012 establishing the best available techniques (BAT) conclusions under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions for the manufacture of glass (notified under document C(2012) 865) (Text with EEA relevance) (2012/134/EU)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2012-134",
  "path": "annex/division/5/division/1.6/division/1.6.2/division/50",
  "kind": "division",
  "number": "50",
  "heading": null,
  "text": "When nitrates are used in the batch formulation, BAT is to reduce NOX emissions by minimising the use of these raw materials, in combination with either primary or secondary techniques\nA description of the technique is given in Section 1.10.2.\nTechnique\nApplicability\nPrimary techniques\nminimising the use of nitrates in the batch formulation\nThe use of nitrates is applied for very high quality products, where special characteristics of the glass are required. Effective alternative materials are sulphates, arsenic oxides, cerium oxide\nThe substitution of nitrates in the batch formulation may be limited by the high costs and/or higher environmental impact of the alternative materials\nTable 40\nBAT-AELs for NOX emissions from the melting furnace in the special glass sector when nitrates are used in the batch formulation\nThe lower levels are associated with the use of electric melting.\nThe conversion factors of 2,5 × 10–3 and 6,5 × 10–3 have been used for the determination of the lower and upper value of the BAT-AEL range respectively, with values being approximated. A case-by-case conversion factor may have to be applied based on the type of production (see Table 2).\nParameter\nBAT\nBAT-AEL\nmg/Nm3\nkg/tonne melted glass\nNOX expressed as NO2\nMinimisation of nitrate input in the batch formulation combined with primary or secondary techniques\n< 500 – 1 000\n< 1 – 6",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "A description of the technique is given in Section 1.10.2."
    },
    {
      "type": "footnote",
      "label": "f2",
      "text": "The lower levels are associated with the use of electric melting."
    },
    {
      "type": "footnote",
      "label": "f3",
      "text": "The conversion factors of 2,5 × 10–3 and 6,5 × 10–3 have been used for the determination of the lower and upper value of the BAT-AEL range respectively, with values being approximated. A case-by-case conversion factor may have to be applied based on the type of production (see Table 2)."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2012/134/annex/division/5/division/1.6/division/1.6.2/division/50",
    "retrieved_at": "2026-11-01T15:15:31.348652+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}