# Commission Implementing Decision of 28 February 2012 establishing the best available techniques (BAT) conclusions under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions for the manufacture of glass (notified under document C(2012) 865) (Text with EEA relevance) (2012/134/EU), Division 70

Extent: E+W+S+N.I.

BAT is to reduce volatile organic compound (VOC) emissions from the lubricant burn-off oven by using one or a combination of the following techniques:
A description of the techniques is given in Sections 1.10.6 and 1.10.9.
Technique
Applicability
(i)
Combustion control, including monitoring the associated emissions of CO.
The technique consists of the control of combustion parameters (e.g. oxygen content in the reaction zone, flame temperature) in order to ensure a complete combustion of the organic components (i.e. polyethylene glycol) in the waste gas. The monitoring of carbon monoxide emissions allows for controlling the presence of uncombusted organic materials
The technique is generally applicable
(ii)
Waste gas incineration
The economic viability may limit the applicability of these techniques because of low waste gas volumes and VOC concentrations
(iii)
Wet scrubbers
Table 60
BAT-AELs for VOC emissions from the lubricant burn-off oven in the HTIW sector, when treated separately
Parameter
BAT
BAT-AEL
mg/Nm3
Volatile organic compounds expressed as C
Primary and/or secondary techniques
10 – 20

---