  "url": "https://openlegislation.uk/eu-decision-2012-134/annex/division-5/division-1.9/division-1.9.1/division-71",
  "json_url": "https://openlegislation.uk/eu-decision-2012-134/annex/division-5/division-1.9/division-1.9.1/division-71.json",
  "legislation": "eudn/2012/134",
  "legislation_title": "Commission Implementing Decision of 28 February 2012 establishing the best available techniques (BAT) conclusions under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions for the manufacture of glass (notified under document C(2012) 865) (Text with EEA relevance) (2012/134/EU)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2012-134",
  "path": "annex/division/5/division/1.9/division/1.9.1/division/71",
  "kind": "division",
  "number": "71",
  "heading": null,
  "text": "BAT is to reduce dust emissions from the waste gases of the melting furnace by means of an electrostatic precipitator or a bag filter system.\nA description of the technique is given in Section 1.10.1.\nTechnique\nApplicability\nFiltration system: electrostatic precipitator or bag filter\nThe technique is generally applicable\nTable 61\nBAT-AELs for dust emissions from the melting furnace in the frits sector\nThe conversion factors of 5 × 10–3 and 7,5 × 10–3 have been used for the determination of the lower and upper value of the BAT-AELs range (see Table 2). However, a case-by-case conversion factor may have to be applied based on the type of combustion.\nParameter\nBAT-AEL\nmg/Nm3\nkg/tonne melted glass\nDust\n< 10 – 20\n< 0,05 – 0,15",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "A description of the technique is given in Section 1.10.1."
    },
    {
      "type": "footnote",
      "label": "f2",
      "text": "The conversion factors of 5 × 10–3 and 7,5 × 10–3 have been used for the determination of the lower and upper value of the BAT-AELs range (see Table 2). However, a case-by-case conversion factor may have to be applied based on the type of combustion."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2012/134/annex/division/5/division/1.9/division/1.9.1/division/71",
    "retrieved_at": "2026-11-01T15:15:31.348652+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}