  "url": "https://openlegislation.uk/eu-decision-2012-134/annex/division-5/division-1.9/division-1.9.3/division-73",
  "json_url": "https://openlegislation.uk/eu-decision-2012-134/annex/division-5/division-1.9/division-1.9.3/division-73.json",
  "legislation": "eudn/2012/134",
  "legislation_title": "Commission Implementing Decision of 28 February 2012 establishing the best available techniques (BAT) conclusions under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions for the manufacture of glass (notified under document C(2012) 865) (Text with EEA relevance) (2012/134/EU)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2012-134",
  "path": "annex/division/5/division/1.9/division/1.9.3/division/73",
  "kind": "division",
  "number": "73",
  "heading": null,
  "text": "BAT is to control SOX emissions from the melting furnace by using one or a combination of the following techniques:\nA description of the techniques is given in Section 1.10.3.\nTechnique\nApplicability\n(i)\nSelection of raw materials for the batch formulation with a low content of sulphur\nThe technique is generally applicable within the constraints of the availability of raw materials\n(ii)\nDry or semi-dry scrubbing, in combination with a filtration system\nThe technique is generally applicable\n(iii)\nUse of low sulphur content fuels\nThe applicability may be limited by the constraints associated with the availability of low sulphur fuels, which may be impacted by the energy policy of the Member State\nTable 63\nBAT-AELs for SOX emissions from the melting furnace in the frits sector\nThe conversion factors of 5 × 10–3 and 7,5 × 10–3 have been used; however, the values indicated in the table may have been approximated. A case-by-case conversion factor may have to be applied based on the type of combustion (see Table 2).\nParameter\nBAT-AEL\nmg/Nm3\nkg/tonne melted glass\nSOX, expressed as SO2\n< 50 – 200\n< 0,25 – 1,5",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "A description of the techniques is given in Section 1.10.3."
    },
    {
      "type": "footnote",
      "label": "f2",
      "text": "The conversion factors of 5 × 10–3 and 7,5 × 10–3 have been used; however, the values indicated in the table may have been approximated. A case-by-case conversion factor may have to be applied based on the type of combustion (see Table 2)."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2012/134/annex/division/5/division/1.9/division/1.9.3/division/73",
    "retrieved_at": "2026-11-01T15:15:31.348652+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}