BAT for secondary emissions from sinter strand discharge, sinter crushing, cooling, screening and conveyor transfer points is to prevent dust emissions and/or to achieve an efficient extraction and subsequently to reduce dust emissions by using a combination of the following techniques:

  1. I..

    hooding and/or enclosure

  2. II..

    an electrostatic precipitator or a bag filter.

The BAT-associated emission level for dust is < 10 mg/Nm3 for the bag filter and < 30 mg/Nm3 for the electrostatic precipitator, both determined as a daily mean value.