Division 51
United Kingdom
BAT for coke quenching is to reduce dust emissions by using one of the following techniques:
- I..
using coke dry quenching (CDQ) with the recovery of sensible heat and the removal of dust from charging, handling and screening operations by means of a bag filter
- II..
using emission-minimised conventional wet quenching
- III..
using coke stabilisation quenching (CSQ).
The BAT-associated emission levels for dust, determined as the average over the sampling period, are:
Annotations
Footnotes
- f1
-
This level is based on the use of the non-isokinetic Mohrhauer method (former VDI 2303)
- f2
-
This level is based on the use of an isokinetic sampling method according to VDI 2066