BAT is to reduce dust emissions from the blast furnace gas by using one or a combination of the following techniques:

  1. I..

    using dry prededusting devices such as:

    1. (i)

      deflectors

    2. (ii)

      dust catchers

    3. (iii)

      cyclones

    4. (iv)

      electrostatic precipitators.

  2. II..

    subsequent dust abatement such as:

    1. (i)

      hurdle-type scrubbers

    2. (ii)

      venturi scrubbers

    3. (iii)

      annular gap scrubbers

    4. (iv)

      wet electrostatic precipitators

    5. (v)

      disintegrators.