Division 64
United Kingdom
BAT is to reduce dust emissions from the blast furnace gas by using one or a combination of the following techniques:
- I..
using dry prededusting devices such as:
- (i)
deflectors
- (ii)
dust catchers
- (iii)
cyclones
- (iv)
electrostatic precipitators.
- (i)
- II..
subsequent dust abatement such as:
- (i)
hurdle-type scrubbers
- (ii)
venturi scrubbers
- (iii)
annular gap scrubbers
- (iv)
wet electrostatic precipitators
- (v)
disintegrators.
- (i)
For cleaned blast furnace (BF) gas, the residual dust concentration associated with BAT is < 10 mg/Nm3, determined as the average over the sampling period (discontinuous measurement, spot samples for at least half an hour).