Division 76
United Kingdom
BAT for basic oxygen furnace (BOF) gas recovery during oxygen blowing in the case of full combustion is to reduce dust emissions by using one of the following techniques:
- I..
dry dedusting (e.g. ESP or bag filter) for new and existing plants
- II..
wet dedusting (e.g. wet ESP or scrubber) for existing plants.
The BAT-associated emission levels for dust, determined as the average over the sampling period (discontinuous measurement, spot samples for at least half an hour), are:
-
10 – 30 mg/Nm3 for BAT I
-
< 50 mg/Nm3 for BAT II.