Division 92
United Kingdom
BAT is to minimise the waste water discharge from continuous casting by using the following techniques in combination:
- I..
the removal of solids by flocculation, sedimentation and/or filtration
- II..
the removal of oil in skimming tanks or in any other effective device
- III..
the recirculation of cooling water and water from vacuum generation as much as possible.
The BAT-associated emission levels, for waste water from continuous casting machines, based on a qualified random sample or a 24-hour composite sample, are:
— suspended solids — iron — zinc — nickel — total chromium — total hydrocarbons
< 20 mg/l
< 5 mg/l
< 2 mg/l
< 0,5 mg/l
< 0,5 mg/l
< 5 mg/l