Annex I
United Kingdom
ANNEX A
References
For each reference made in the basic parameters (Chapter 4 of this TSI) the following table indicates the corresponding mandatory specifications, via the index in table A-2.
Table A 1
Reference in Chapter 4 Index number (see Table A 2) 4.1 4.1 a 1, 4 4.1 b 32 4.1 c 3 4.2.1 4.2.1 a 27, 78 4.2.1 b 28 4.2.2 4.2.2.a 14 4.2.2.b 1, 4, 13, 15, 60 4.2.2.c 31, 37b, c, d 4.2.2.d 18, 20 4.2.2.e 6 4.2.2.f 7 4.2.3 4.2.3 a 14 4.2.3 b 1, 4, 13, 15, 60 4.2.3 c 31, 37 b, c, d 4.2.3 d 18, 21 4.2.4 4.2.4 a 64, 65 4.2.4 b 66 4.2.4 c 67 4.2.4 d 68 4.2.4 e 73, 74 4.2.4 f 32, 33 4.2.4 g 48 4.2.4 h 69, 70 4.2.4 j 71, 72 4.2.4 k 75, 76 4.2.5 4.2.5 a 64, 65 4.2.5 b 10, 39, 40 4.2.5 c 19, 20 4.2.5 d 9, 43 4.2.5 e 16, 50 4.2.6 4.2.6 a 8, 25, 26, 36 c, 49, 52 4.2.6 b 29, 45 4.2.6 c 46 4.2.6 d 34 4.2.6 e 20 4.2.6 f 44 4.2.7 4.2.7 a 12 4.2.7 b 62, 63 4.2.7 c 34 4.2.7 d 9 4.2.7 e 16 4.2.8 4.2.8 a 11, 79 4.2.9 4.2.9 a 23 4.2.10 4.2.10 a 77 (section 3.1) 4.2.11 4.2.11 a 77 (section 3.2) 4.2.12 4.2.12 a 6, 51 4.2.13 4.2.13 a 32, 33, 51, 80 4.2.14 4.2.14 a 5 4.2.15 4.2.15 a 38 Specifications
One of the two sets of specifications listed in Table A-2 of this Annex shall be applied.
Documents referred to within a specification listed in Table A-2 shall be considered as being for information only, unless otherwise stated in Table A-2.
Note:
specifications indicated as ‘Reserved’ in table A-2 are also listed as open points in Annex G when there is a need for notification of national rules to close the corresponding open points. Reserved documents not listed as open points are intended as improvements to the system.
Table A 2
List of mandatory specifications
Index N Set of specifications # 1(ETCS baseline 2 and GSM-R baseline 0) Set of specifications # 2(ETCS baseline 3 and GSM-R baseline 0) Reference Name of Specification Version Notes Reference Name of Specification Version Notes 1 ERA/ERTMS/003204 ERTMS/ETCS Functional requirement specification 5.0 Intentionally deleted 2 Intentionally deleted Intentionally deleted 3 UNISIG SUBSET-023 Glossary of Terms and Abbreviations 2.0.0 UNISIG SUBSET-023 Glossary of Terms and Abbreviations 3.0.0 4 UNISIG SUBSET-026 System Requirements Specification 2.3.0 UNISIG SUBSET-026 System Requirements Specification 3.3.0 5 UNISIG SUBSET-027 FFFIS Juridical recorder-downloading tool 2.3.0 Note 1 UNISIG SUBSET-027 FIS Juridical Recording 3.0.0 6 UNISIG SUBSET-033 FIS for man-machine interface 2.0.0 ERA_ERTMS_015560 ETCS Driver Machine interface 3.3.0 7 UNISIG SUBSET-034 FIS for the train interface 2.0.0 UNISIG SUBSET-034 Train Interface FIS 3.0.0 8 UNISIG SUBSET-035 Specific Transmission Module FFFIS 2.1.1 UNISIG SUBSET-035 Specific Transmission Module FFFIS 3.0.0 9 UNISIG SUBSET-036 FFFIS for Eurobalise 2.4.1 UNISIG SUBSET-036 FFFIS for Eurobalise 3.0.0 10 UNISIG SUBSET-037 EuroRadio FIS 2.3.0 UNISIG SUBSET-037 EuroRadio FIS 3.0.0 11 UNISIG SUBSET-038 Offline key management FIS 2.3.0 UNISIG SUBSET-038 Offline key management FIS 3.0.0 12 UNISIG SUBSET-039 FIS for the RBC/RBC handover 2.3.0 Reserved
UNISIG SUBSET-039
FIS for the RBC/RBC handover 13 UNISIG SUBSET-040 Dimensioning and Engineering rules 2.3.0 UNISIG SUBSET-040 Dimensioning and Engineering rules 3.2.0 14 UNISIG SUBSET-041 Performance Requirements for Interoperability 2.1.0 UNISIG SUBSET-041 Performance Requirements for Interoperability 3.1.0 15 ERA SUBSET-108 Interoperability related consolidation on TSI Annex A documents 1.2.0 Intentionally deleted 16 UNISIG SUBSET-044 FFFIS for Euroloop 2.3.0 UNISIG SUBSET-044 FFFIS for Euroloop 2.4.0 17 Intentionally deleted Intentionally deleted 18 UNISIG SUBSET-046 Radio infill FFFS 2.0.0 Intentionally deleted 19 UNISIG SUBSET-047 Trackside-Trainborne FIS for Radio infill 2.0.0 UNISIG SUBSET-047 Trackside-Trainborne FIS for Radio infill 3.0.0 20 UNISIG SUBSET-048 Trainborne FFFIS for Radio infill 2.0.0 UNISIG SUBSET-048 Trainborne FFFIS for Radio infill 3.0.0 21 UNISIG SUBSET-049 Radio infill FIS with LEU/interlocking 2.0.0 Intentionally deleted 22 Intentionally deleted Intentionally deleted 23 UNISIG SUBSET-054 Responsibilities and rules for the assignment of values to ETCS variables 2.1.0 UNISIG SUBSET-054 Responsibilities and rules for the assignment of values to ETCS variables 3.0.0 24 Intentionally deleted Intentionally deleted 25 UNISIG SUBSET-056 STM FFFIS Safe time layer 2.2.0 UNISIG SUBSET-056 STM FFFIS Safe time layer 3.0.0 26 UNISIG SUBSET-057 STM FFFIS Safe link layer 2.2.0 UNISIG SUBSET-057 STM FFFIS Safe link layer 3.0.0 27 UNISIG SUBSET-091 Safety Requirements for the Technical Interoperability of ETCS in Levels 1 and 2 2.5.0 UNISIG SUBSET-091 Safety Requirements for the Technical Interoperability of ETCS in Levels 1 and 2 3.2.0 28 Reserved Reliability — availability requirements Reserved Reliability — availability requirements 29 UNISIG SUBSET-102 Test specification for interface ‘K’ 1.0.0 UNISIG SUBSET-102 Test specification for interface ‘K’ 2.0.0 30 Intentionally deleted Intentionally deleted 31 UNISIG SUBSET-094 Functional requirements for an on-board reference test facility 2.0.2 Reserved
UNISIG SUBSET-094
Functional requirements for an on-board reference test facility 32 EIRENE FRS GSM-R Functional requirements specification 7.3.0 EIRENE FRS GSM-R Functional requirements specification 7.3.0 33 EIRENE SRS GSM-R System requirements specification 15.3.0 EIRENE SRS GSM-R System requirements specification 15.3.0 34 A11T6001 (MORANE) Radio Transmission FFFIS for EuroRadio 12.4 A11T6001 (MORANE) Radio Transmission FFFIS for EuroRadio 12.4 35 Intentionally deleted Intentionally deleted 36 a Intentionally deleted Intentionally deleted 36 b Intentionally deleted Intentionally deleted 36 c UNISIG SUBSET-074-2 FFFIS STM Test cases document 1.0.0 Reserved
UNISIG SUBSET-074-2
FFFIS STM Test cases document 37 a Intentionally deleted Intentionally deleted 37 b UNISIG SUBSET-076-5-2 Test cases related to features 2.3.3 Reserved
UNISIG SUBSET-076-5-2
Test cases related to features 37 c UNISIG SUBSET-076-6-3 Test sequences 2.3.3 Reserved
UNISIG SUBSET-076-6-3
Test sequences 37 d UNISIG SUBSET-076-7 Scope of the test specifications 1.0.2 Reserved
UNISIG SUBSET-076-7
Scope of the test specifications 37 e Intentionally deleted Intentionally deleted 38 06E068 ETCS Marker-board definition 2.0 06E068 ETCS Marker-board definition 2.0 39 UNISIG SUBSET-092-1 ERTMS EuroRadio Conformance Requirements 2.3.0 UNISIG SUBSET-092-1 ERTMS EuroRadio Conformance Requirements 3.0.0 40 UNISIG SUBSET-092-2 ERTMS EuroRadio test cases safety layer 2.3.0 UNISIG SUBSET-092-2 ERTMS EuroRadio test cases safety layer 3.0.0 41 Intentionally deleted Intentionally deleted 42 Intentionally deleted Intentionally deleted 43 UNISIG SUBSET 085 Test specification for Eurobalise FFFIS 2.2.2 UNISIG SUBSET 085 Test specification for Eurobalise FFFIS 3.0.0 44 Reserved Odometry FIS Reserved Odometry FIS 45 UNISIG SUBSET-101 Interface ‘K’ Specification 1.0.0 UNISIG SUBSET-101 Interface ‘K’ Specification 2.0.0 46 UNISIG SUBSET-100 Interface ‘G’ Specification 1.0.1 UNISIG SUBSET-100 Interface ‘G’ Specification 2.0.0 47 Intentionally deleted Intentionally deleted 48 Reserved Test specification for mobile equipment GSM-R Reserved Test specification for mobile equipment GSM-R 49 UNISIG SUBSET-059 Performance requirements for STM 2.1.1 UNISIG SUBSET-059 Performance requirements for STM 3.0.0. 50 UNISIG SUBSET-103 Test specification for Euroloop 1.0.0 UNISIG SUBSET-103 Test specification for Euroloop 1.1.0 51 Reserved Ergonomic aspects of the DMI Intentionally deleted 52 UNISIG SUBSET-058 FFFIS STM Application layer 2.1.1 UNISIG SUBSET-058 FFFIS STM Application layer 3.0.0 53 Intentionally deleted Intentionally deleted 54 Intentionally deleted Intentionally deleted 55 Intentionally deleted Intentionally deleted 56 Intentionally deleted Intentionally deleted 57 Intentionally deleted Intentionally deleted 58 Intentionally deleted Intentionally deleted 59 Intentionally deleted Intentionally deleted 60 Intentionally deleted UNISIG SUBSET-104 ETCS System Version Management 3.1.0 61 Intentionally deleted Intentionally deleted 62 Reserved RBC-RBC Test specification for safe communication interface Intentionally deleted 63 UNISIG SUBSET-098 RBC-RBC Safe Communication Interface 1.0.0 UNISIG SUBSET-098 RBC-RBC Safe Communication Interface 3.0.0 64 EN 301 515 Global System for Mobile Communication (GSM);
Requirements for GSM operation on railways
2.3.0 Note 2 EN 301 515 Global System for Mobile Communication (GSM);
Requirements for GSM operation on railways
2.3.0 Note 2 65 TS 102 281 Detailed requirements for GSM operation on railways 2.2.0 Note 3 TS 102 281 Detailed requirements for GSM operation on railways 2.2.0 Note 3 66 (MORANE) A 01 T 0004 1 ASCI Options for Interoperability 1 (MORANE) A 01 T 0004 1 ASCI Options for Interoperability 1 67 (MORANE) P 38 T 9001 FFFIS for GSM-R SIM Cards 4.1 (MORANE) P 38 T 9001 FFFIS for GSM-R SIM Cards 4.1 68 ETSI TS 102 610 Railway Telecommunication; GSM;
Usage of the UUIE for GSM operation on railways
1.1.0 ETSI TS 102 610 Railway Telecommunication; GSM;
Usage of the UUIE for GSM operation on railways
1.1.0 69 (MORANE) F 10 T 6002 FFFS for Confirmation of High Priority Calls’ 4 (MORANE) F 10 T 6002 FFFS for Confirmation of High Priority Calls’ 4 70 (MORANE) F 12 T 6002 FIS for Confirmation of High Priority Calls 4 (MORANE) F 12 T 6002 FIS for Confirmation of High Priority Calls 4 71 (MORANE) E 10 T 6001 FFFS for Functional Addressing 4 (MORANE) E 10 T 6001 FFFS for Functional Addressing 4 72 (MORANE) E 12 T 6001 FIS for Functional Addressing 5.1 (MORANE) E 12 T 6001 FIS for Functional Addressing 5.1 73 (MORANE) F 10 T6001 FFFS for Location Dependent Addressing 4 (MORANE) F 10 T6001 FFFS for Location Dependent Addressing 4 74 (MORANE) F 12 T6001 FIS for Location Dependent Addressing 3 (MORANE) F 12 T6001 FIS for Location Dependent Addressing 3 75 (MORANE) F 10 T 6003 FFFS for Presentation of Functional Numbers to Called and Calling Parties 4 (MORANE) F 10 T 6003 FFFS for Presentation of Functional Numbers to Called and Calling Parties 4 76 (MORANE) F 12 T 6003 FIS for Presentation of Functional Numbers to Called and Calling Parties 4 (MORANE) F 12 T 6003 FIS for Presentation of Functional Numbers to Called and Calling Parties 4 77 ERA/ERTMS/033281 Interfaces between CCS track-side and other subsystems 1.0 ERA/ERTMS/033281 Interfaces between CCS track-side and other subsystems 1.0 78 Reserved Safety requirements for ETCS DMI functions Reserved Safety requirements for ETCS DMI functions 79 Not applicable Not applicable UNISIG SUBSET-114 KMC-ETCS Entity Off-line KM FIS 1.0.0 80 Not applicable Not applicable Reserved GSM-R Driver Machine Interface Note 1:
only the functional description of information to be recorded is mandatory, not the technical characteristics of the interface.
Note 2:
the specifications listed in section 2.1 of EN 301 515 are mandatory.
Note 3:
the change requests (CRs) listed in table 1 and 2 of TR 102 281 are mandatory.
Table A 3
List of mandatory standards
The standards listed in this table shall be applied in the certification process, without prejudice to chapter 4 and chapter 6 of this TSI.
No Reference Document name and comments Version A1 EN 50126 Railway applications — The specification and demonstration of reliability, availability, maintainability and safety (RAMS) 1999 A2 EN 50128 Railway applications — Communication, signalling and processing systems — Software for railway control and protection systems 2001 A3 EN 50129 Railway applications — Communication, signalling and processing systems — Safety related electronic systems for signalling 2003 A4 EN 50159-1 Railway applications — Communication, signalling and processing systems — Part 1: Safety related communication in closed transmission systems 2001 A5 EN 50159-2 Railway applications — Communication, signalling and processing systems — Part 2: Safety related communication in open transmission systems 2001