  "url": "https://openlegislation.uk/eu-decision-2013-163/annex/division-5/division-1.2/division-1.2.5/division-1.2.5.1/division-15",
  "json_url": "https://openlegislation.uk/eu-decision-2013-163/annex/division-5/division-1.2/division-1.2.5/division-1.2.5.1/division-15.json",
  "legislation": "eudn/2013/163",
  "legislation_title": "Commission Implementing Decision of 26 March 2013 establishing the best available techniques (BAT) conclusions under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions for the production of cement, lime and magnesium oxide (notified under document C(2013) 1728) (Text with EEA relevance) (2013/163/EU)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2013-163",
  "path": "annex/division/5/division/1.2/division/1.2.5/division/1.2.5.1/division/15",
  "kind": "division",
  "number": "15",
  "heading": null,
  "text": "In order to minimise/prevent diffuse dust emissions from bulk storage areas, BAT is to use one or a combination of the following techniques:\nTechnique\na\nCover bulk storage areas or stockpiles or enclose them with screening, walling or an enclosure consisting of vertical greenery (artificial or natural wind barriers for open pile wind protection)\nb\nUse open pile wind protection:\nOutdoor storage piles of dusty materials should be avoided, but when they do exist it is possible to reduce diffuse dust by using properly designed wind barriers\nc\nUse water spray and chemical dust suppressors:\nWhen the point source of diffuse dust is well localised, a water spray injection system can be installed. The humidification of dust particles aids agglomeration and so helps dust settle. A wide variety of agents is also available to improve the overall efficiency of the water spray\nd\nEnsure paving, road wetting and housekeeping:\nAreas used by lorries should be paved when possible and the surface should be kept as clean as possible. Wetting the roads can reduce diffuse dust emissions, especially during dry weather. They also can be cleaned with road sweepers. Good housekeeping practices should be used in order to keep diffuse dust emissions to a minimum\ne\nEnsure humidification of stockpiles:\nDiffuse dust emissions at stockpiles can be reduced by using sufficient humidification of the charging and discharging points, and by using conveyor belts with adjustable heights\nf\nMatch the discharge height to the varying height of the heap, automatically if possible or by reduction of the unloading velocity, when diffuse dust emissions at the charging or discharging points of storage sites cannot be avoided",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2013/163/annex/division/5/division/1.2/division/1.2.5/division/1.2.5.1/division/15",
    "retrieved_at": "2026-11-01T15:15:07.930990+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}