  "url": "https://openlegislation.uk/eu-decision-2013-163/annex/division-5/division-1.2/division-1.2.6/division-1.2.6.3/division-1.2.6.3.1/division-23/division-1",
  "json_url": "https://openlegislation.uk/eu-decision-2013-163/annex/division-5/division-1.2/division-1.2.6/division-1.2.6.3/division-1.2.6.3.1/division-23/division-1.json",
  "legislation": "eudn/2013/163",
  "legislation_title": "Commission Implementing Decision of 26 March 2013 establishing the best available techniques (BAT) conclusions under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions for the production of cement, lime and magnesium oxide (notified under document C(2013) 1728) (Text with EEA relevance) (2013/163/EU)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2013-163",
  "path": "annex/division/5/division/1.2/division/1.2.6/division/1.2.6.3/division/1.2.6.3.1/division/23/division/1",
  "kind": "division",
  "number": null,
  "heading": "Description",
  "text": "For safety reasons, due to the risk of explosions, ESPs will have to shut down during elevated CO levels in the flue-gases. The following techniques prevent CO trips and, therefore, reduce ESP shutdown times:\ncontrol of the combustion process\ncontrol of the organic load of raw materials\ncontrol of the quality of the fuels and fuel feeding system.\nDisruptions predominantly happen during the start-up operation phase. For safe operation, the gas analysers for ESP protection have to be on-line during all operational phases and the ESP downtime can be reduced by using a backup monitoring system maintained in operation.\nThe continuous CO monitoring system needs to be optimised for reaction time and should be located close to the CO source, e.g. at a preheater tower outlet, or at a kiln inlet in the case of a wet kiln application.\nWhen hybrid filters are used, the grounding of the bag support cage with the cell plate is recommended.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2013/163/annex/division/5/division/1.2/division/1.2.6/division/1.2.6.3/division/1.2.6.3.1/division/23/division/1",
    "retrieved_at": "2026-11-01T15:15:07.930990+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}