  "url": "https://openlegislation.uk/eu-decision-2013-163/annex/division-5/division-1.3/division-1.3.6/division-1.3.6.1/division-41",
  "json_url": "https://openlegislation.uk/eu-decision-2013-163/annex/division-5/division-1.3/division-1.3.6/division-1.3.6.1/division-41.json",
  "legislation": "eudn/2013/163",
  "legislation_title": "Commission Implementing Decision of 26 March 2013 establishing the best available techniques (BAT) conclusions under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions for the production of cement, lime and magnesium oxide (notified under document C(2013) 1728) (Text with EEA relevance) (2013/163/EU)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2013-163",
  "path": "annex/division/5/division/1.3/division/1.3.6/division/1.3.6.1/division/41",
  "kind": "division",
  "number": "41",
  "heading": null,
  "text": "In order to minimise/prevent diffuse dust emissions from bulk storage areas, BAT is to use one or a combination of the following techniques:\nTechnique\na\nEnclose storage locations using screening, walling or vertical greenery (artificial or natural wind barriers for open pile wind protection)\nb\nUse product silos and closed, fully-automated raw material storages. These types of storage are equipped with one or more fabric filters to prevent diffuse dust formation in loading and unloading operations\nc\nReduce diffuse dust emissions at stockpiles by using sufficient humidification of stockpile charging and discharging points and the use of conveyor belts with adjustable height. When using humidification or spraying measures/techniques, the ground can be sealed and the surplus water can be gathered, and if necessary this can be treated and used in closed cycles\nd\nReduce diffuse dust emissions at charging or discharging points of storage sites if they cannot be avoided, by matching the discharge height to the varying height of the heap, if possible automatically, or by reduction of the unloading velocity\ne\nKeep the locations wet, especially dry areas, using spraying devices and clean them by cleaning lorries\nf\nUse vacuum systems during removal operations. New buildings can easily be equipped with stationary vacuum cleaning systems, while existing buildings are normally better fitted with mobile systems and flexible connections\ng\nReduce diffuse dust emissions arising in areas used by lorries, by paving these areas when possible and keeping the surface as clean as possible. Wetting the roads can reduce diffuse dust emissions, especially during dry weather. Good housekeeping practices can be used in order to keep diffuse dust emissions to a minimum",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2013/163/annex/division/5/division/1.3/division/1.3.6/division/1.3.6.1/division/41",
    "retrieved_at": "2026-11-01T15:15:07.930990+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}