# Commission Implementing Decision of 26 September 2014 establishing the best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council, for the production of pulp, paper and board (notified under document C(2014) 6750) (Text with EEA relevance) (2014/687/EU), Division BAT 39: In order to increase the efficiency of power generation, BAT is to use a combination of the techniques given below.

Extent: E+W+S+N.I.

Technique
a
High recovery boiler pressure and temperature
b
Outlet steam pressure in the back-pressure turbine as low as technically feasible
c
Condensing turbine for power production from excess steam
d
High turbine efficiency
e
Preheating feedwater to a temperature close to the boiling temperature
f
Preheating the combustion air and fuel charged to the boilers

---
Source: https://www.legislation.gov.uk/eudn/2014/687/annex/division/9/division/1.3/division/1.3.3/division/bat+39 (the official version)