{
  "url": "https://openlegislation.uk/eu-decision-2014-687/annex/division-9/division-1.5/division-1.5.1/division-bat+42",
  "json_url": "https://openlegislation.uk/eu-decision-2014-687/annex/division-9/division-1.5/division-1.5.1/division-bat+42.json",
  "legislation": "eudn/2014/687",
  "legislation_title": "Commission Implementing Decision of 26 September 2014 establishing the best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council, for the production of pulp, paper and board (notified under document C(2014) 6750) (Text with EEA relevance) (2014/687/EU)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2014-687",
  "path": "annex/division/9/division/1.5/division/1.5.1/division/bat+42",
  "kind": "division",
  "number": "BAT 42",
  "heading": "In order to prevent the contamination of soil and groundwater or to reduce the risk thereof and in order to reduce wind drift of paper for recycling and diffuse dust emissions from the paper for recycling yard, BAT is to use one or a combination of the techniques given below.",
  "text": "Technique\nApplicability\na\nHard surfacing of the storage area for paper for recycling\nGenerally applicable\nb\nCollection of contaminated run-off water from the paper for recycling storage area and treatment in a waste water treatment plant (uncontaminated rainwater e.g. from roofs can be discharged separately)\nApplicability may be restricted by the degree of contamination of run-off water (low concentration) and/or the size of the waste water treatment plants (large volumes)\nc\nSurrounding the terrain of the paper for recycling yard with fences against wind drift\nGenerally applicable\nd\nRegularly cleaning the storage area and sweeping associated roadways and emptying gully pots to reduce diffuse dust emissions. This reduces wind-blown paper debris, fibres and the crushing of paper by on-site traffic, which can cause additional dust emission, especially in the dry season\nGenerally applicable\ne\nStoring of bales or loose paper under a roof to protect the material from weather influences (moisture, microbiological degradation processes, etc.)\nApplicability may be restricted by the size of the area",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2014/687/annex/division/9/division/1.5/division/1.5.1/division/bat+42",
    "retrieved_at": "2026-11-01T15:14:38.312084+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}