  "url": "https://openlegislation.uk/eu-decision-2014-738/annex/division-4/division-1.20/division-1.20.7",
  "json_url": "https://openlegislation.uk/eu-decision-2014-738/annex/division-4/division-1.20/division-1.20.7.json",
  "legislation": "eudn/2014/738",
  "legislation_title": "Commission Implementing Decision of 9 October 2014 establishing best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions, for the refining of mineral oil and gas (notified under document C(2014) 7155) (Text with EEA relevance) (2014/738/EU)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2014-738",
  "path": "annex/division/4/division/1.20/division/1.20.7",
  "kind": "division",
  "number": "1.20.7",
  "heading": "Other techniques",
  "text": "Technique\nDescription\nTechniques to prevent or reduce emissions from flaring\nCorrect plant design includes sufficient flare gas recovery system capacity, the use of high-integrity relief valves and other measures to use flaring only as a safety system for other than normal operations (start-up, shutdown, emergency).\nPlant management includes organisational and control measures to reduce flaring events by balancing RFG system, using advanced process control, etc.\nFlaring devices design includes height, pressure, assistance by steam, air or gas, type of flare tips, etc. It aims at enabling smokeless and reliable operations and ensuring an efficient combustion of excess gases when flaring from non-routine operations.\nMonitoring and reporting Continuous monitoring (measurements of gas flow and estimations of other parameters) of gas sent to flaring and associated parameters of combustion (e.g. flow gas mixture and heat content, ratio of assistance, velocity, purge gas flow rate, pollutant emissions). Reporting of flaring events makes it possible to use flaring ratio as a requirement included in the EMS and to prevent future events.\nVisual remote monitoring of the flare can also be carried out by using colour TV monitors during flare events\nChoice of the catalyst promoter to avoid dioxins formation\nDuring the regeneration of the reformer catalyst, organic chloride is generally needed for effective reforming catalyst performance (to re-establish the proper chloride balance in the catalyst and to assure the correct dispersion of the metals). The choice of the appropriate chlorinated compound will have an influence on the possibility of emissions of dioxins and furans\nSolvent recovery for base oil production processes\nThe solvent recovery unit consists of a distillation step where the solvents are recovered from the oil stream and a stripping step (with steam or an inert gas) in a fractionator.\nThe solvents used may be a mixture (DiMe) of 1,2-dichloroethane (DCE) and dichloromethane (DCM).\nIn wax-processing units, solvent recovery (e.g. for DCE) is carried out using two systems: one for the deoiled wax and another one for the soft wax. Both consist of heat-integrated flashdrums and a vacuum stripper. Streams from the dewaxed oil and waxes product are stripped for removal of traces of solvents",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "X",
      "label": "X1",
      "text": "Inserted by Corrigendum to Commission Implementing Decision 2014/738/EU of 9 October 2014 establishing best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions, for the refining of mineral oil and gas (Official Journal of the European Union L 307 of 28 October 2014)."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2014/738/annex/division/4/division/1.20/division/1.20.7",
    "retrieved_at": "2026-11-01T15:14:36.977162+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}