OpenLegislation

Division 2 The testing procedure

United Kingdom

Original text. Later amendments are not shown.

The peak power output (PP) of the PV panel is to be determined experimentally for each vehicle variant. Measurements are to be done in accordance with the testing methodology specified in the international standard IEC 61215:2005f1.

A dismantled complete PV panel is to be used. The four corner points of the panel are to touch the horizontal measurement panel.

The measurements are to be done at least five times.

The lengthwise inclination angle and total storage capacity (or resulting Solar Correction Coefficient (SCC)) is to be supplied by the manufacturer of the vehicle.

The possible lengthwise inclination of the car roof is to be corrected mathematically afterwards by applying a cosine function.

Annotations

Footnotes

f1

IEC 61215. Crystalline silicon terrestrial photovoltaic (PV) modules — Design qualification and type-approval. Reference number IEC 61215:2005(E).