# Commission Implementing Decision (EU) 2015/1183 of 17 July 2015 setting out the necessary technical and operational specifications for implementing version 3 of the EGNOS system, Division 3: EGNOS Data Access service (EDAS) technical and operational specifications

Extent: E+W+S+N.I.

Latency is the time elapsed since the transmission of the last bit of the navigation message from the space segment (EGNOS and GPS/Galileo satellites) until the data leave the EGNOS server.
EDAS
Service specifications
Products provided directly by the system
RIMS raw data
EGNOS broadcast message data
EGNOS health status data
Latency
2 sec
Availability
0,999
Accessibility
Products provided to end users through specific service providers connected to the EGNOS server
Server specifications
Secured architecture for worldwide access
Sufficient bandwidth connectivity

---
Source: https://www.legislation.gov.uk/eudn/2015/1183/annex/division/3 (the official version)