Division I.6.4.1 Preparation of viral RNA
United Kingdom
All work with RNA shall be performed on ice, using gloves.
RNA shall be extracted using the phenol-chloroform method or by RNA affinity spin columns, according to the manufacturer's instructions. Commercially available RNA extraction kits that will produce high quality RNA suitable for use with the RT-PCR protocols detailed in the points below may be used.
RNA shall be re-suspended in distilled RNAse-free water, (namely water treated with 0,1 % diethyl pyrocarbonate) or an appropriate elution buffer.