Division I.6.4.3 RT-qPCR for VHSV
United Kingdom
For VHSV, amplification shall be performed using the following primers and probe:
Forward primer: 5′-AAA-CTC-GCA-GGA-TGT-GTG-CGT-CC-3′;
Reverse primer: 5′-TCT-GCG-ATC-TCA-GTC-AGG-ATG-AA-3′;
and probe: 5′-FAM-TAG-AGG-GCC-TTG-GTG-ATC-TTC-TG-BHQ1.
One-step RT-qPCR:
Negative template controls and positive controls shall be included on each plate run. Cycling conditions: 50 °C for 30 minutes, 95 °C for 15 minutes, 40 cycles of 94 °C for 15 seconds, 60 °C for 40 seconds, 72 °C for 20 seconds; adjust if necessary. Other RT-PCR or RT-qPCR versions of proven similar efficacy may be used instead.