OpenLegislation

Division BAT 14

United Kingdom

Original text. Later amendments are not shown.

In order to prevent or reduce the generation of waste water, BAT is to use one or a combination of the techniques given below.

TechniqueApplicability
aMeasure the amount of fresh water used and the amount of waste water dischargedGenerally applicable
bReuse waste water from cleaning operations (including anode and cathode rinse water) and spills in the same processGenerally applicable
cReuse weak acid streams generated in a wet ESP and wet scrubbersApplicability may be restricted depending on the metal and solid content of the waste water
dReuse waste water from slag granulationApplicability may be restricted depending on the metal and solid content of the waste water
eReuse surface run-off waterGenerally applicable
fUse a closed circuit cooling systemApplicability may be restricted when a low temperature is required for process reasons
gReuse treated water from the waste water treatment plantApplicability may be restricted by the salt content