The BAT-associated emission levels (BAT-AELs) for direct emissions to a receiving water body from the production of copper, lead, tin, zinc, cadmium, precious metals, nickel, cobalt and ferro-alloys are given in Table 2.

These BAT-AELs apply at the point where the emission leaves the installation.

Table 2

BAT-associated emission levels for direct emissions to a receiving water body from the production of copper, lead, tin, zinc (including the waste water from the washing stage in the Waelz kiln process), cadmium, precious metals, nickel, cobalt and ferro-alloys

In the case of a high arsenic content in the total input of the plant, the BAT-AEL may be up to 0,2 mg/l.

NR: Not relevant
BAT-AEL (mg/l) (daily average)
ParameterProduction of
CopperLead and/or TinZinc and/or CadmiumPrecious metalsNickel and/or CobaltFerro-alloys
Silver (Ag)NR≤ 0,6NR
Arsenic (As)≤ 0,1f1 ≤ 0,1≤ 0,1≤ 0,1≤ 0,3≤ 0,1
Cadmium (Cd)0,02–0,1≤ 0,1≤ 0,1≤ 0,05≤ 0,1≤ 0,05
Cobalt (Co)NR≤ 0,1NR0,1-0,5NR
Chromium total (Cr)NR≤ 0,2
Chromium (VI) (Cr(VI))NR≤ 0,05
Copper (Cu)0,05-0,5≤ 0,2≤ 0,1≤ 0,3≤ 0,5≤ 0,5
Mercury (Hg)0,005–0,02≤ 0,05≤ 0,05≤ 0,05≤ 0,05≤ 0,05
Nickel (Ni)≤ 0,5≤ 0,5≤ 0,1≤ 0,5≤ 2≤ 2
Lead (Pb)≤ 0,5≤ 0,5≤ 0,2≤ 0,5≤ 0,5≤ 0,2
Zinc (Zn)≤ 1≤ 1≤ 1≤ 0,4≤ 1≤ 1

Annotations

Footnotes

f1

In the case of a high arsenic content in the total input of the plant, the BAT-AEL may be up to 0,2 mg/l.

Notes on Division BAT 17

Footnotes

f1

Descriptions of the techniques are given in Section 1.10.