In order to reduce diffuse emissions from Peirce-Smith converter (PS) furnace in primary and secondary copper production, BAT is to use a combination of the techniques given below.

Description of the technique is given in Section 1.10.

Technique
aOperate the furnace and gas route under negative pressure and at a sufficient gas extraction rate to prevent pressurisation
bOxygen enrichment
cPrimary hood over the converter opening to collect and transfer the primary emissions to an abatement system
dAddition of materials (e.g. scrap and flux) through the hood
eSystem of secondary hoods in addition to the main one to capture emissions during charging and tapping operations
fFurnace located in enclosed building
gApply motor-driven secondary hoods, to move them according to the process stage, to increase the efficiency of the collection of secondary emissions
hBoosted suction systemsf1 and automatic control to prevent blowing when the converter is ‘rolled out’ or ‘rolled in’

Annotations

Footnotes

f1

Description of the technique is given in Section 1.10.