  "legislation_title": "Commission Implementing Decision (EU) 2016/1032 of 13 June 2016 establishing best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council, for the non-ferrous metals industries (notified under document C(2016) 3563) (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2016-1032",
  "path": "annex/division/1.2/division/1.2.3/division/1.2.3.1/division/bat+30",
  "kind": "division",
  "number": "BAT 30",
  "heading": null,
  "text": "In order to reduce diffuse emissions from a top-blown rotary converter (TBRC) furnace in secondary copper production, BAT is to use a combination of the techniques given below.\nDescription of the technique is given in Section 1.10.\nTechnique\nApplicability\na\nOperate the furnace and gas route under negative pressure and at a sufficient gas extraction rate to prevent pressurisation\nGenerally applicable\nb\nOxygen enrichment\nGenerally applicable\nc\nFurnace located in enclosed building in combination with techniques to collect and transfer diffuse emissions from charging and tapping to an abatement system\nGenerally applicable\nd\nPrimary hood over the converter opening to collect and transfer the primary emissions to an abatement system\nGenerally applicable\ne\nHoods or crane integrated hood to collect and transfer the emissions from charging and tapping operations to an abatement system\nFor existing plants, a crane integrated hood is only applicable to major upgrades of the furnace hall\nf\nAddition of materials (e.g. scrap and flux) through the hood\nGenerally applicable\ng\nBoosted suction system\nGenerally applicable",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "Description of the technique is given in Section 1.10."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2016/1032/annex/division/1.2/division/1.2.3/division/1.2.3.1/division/bat+30",
    "retrieved_at": "2026-11-01T15:13:55.916563+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}