# Commission Implementing Decision (EU) 2016/1032 of 13 June 2016 establishing best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council, for the non-ferrous metals industries (notified under document C(2016) 3563) (Text with EEA relevance), Division 1.3.3.1.2: Total emissions of dust and fluorides

Extent: E+W+S+N.I.

BAT-associated emission levels for the total emissions of dust and fluoride to air from the electrolysis house (collected from the electrolytic cells and roof vents): See Table 12.
Table 12
BAT-associated emission levels for the total emissions of dust and fluoride to air from the electrolysis house (collected from the electrolytic cells and roof vents)
As mass of pollutant emitted during a year from the electrolysis house divided by the mass of liquid aluminium produced in the same year.
These BAT-AELs are not applicable to plants that due to their configuration cannot measure roof emissions.
Parameter
BAT
BAT-AELs for existing plants (kg/t Al)
BAT-AELs for new plants (kg/t Al)
Dust
Combination of BAT 64, BAT 65 and BAT 67
≤ 1,2
≤ 0,6
Total fluorides
≤ 0,6
≤ 0,35
The associated monitoring is in BAT 10.
The associated monitoring is in BAT 10.

---
Source: https://www.legislation.gov.uk/eudn/2016/1032/annex/division/1.3/division/1.3.3/division/1.3.3.1/division/1.3.3.1.2 (the official version)