# Commission Implementing Decision (EU) 2016/1032 of 13 June 2016 establishing best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council, for the non-ferrous metals industries (notified under document C(2016) 3563) (Text with EEA relevance), Division BAT 69

Extent: E+W+S+N.I.

In order to reduce emissions to air from electrolytic cells, BAT is to use one or both of the techniques given below.
Description of the technique is given in Section 1.10.
Technique
Applicability
a
Use of low-sulphur anodes
Generally applicable
b
Wet scrubber
Applicability may be limited in the following cases:
very high off-gas flow rates (due to the significant amounts of waste and waste water generated)
in arid areas (due to the large volume of water necessary and the need for waste water treatment)

---