Division Description
United Kingdom
BAT 69(a): Anodes containing less than 1,5 % sulphur as a yearly average can be produced by an appropriate combination of the raw materials used. A minimum sulphur content of 0,9 % as a yearly average is required for the viability of the electrolysis process.
BAT-associated emission levels: See Table 14.
Table 14
BAT-associated emission levels for SO2 emissions to air from electrolytic cells
| As mass of pollutant emitted during a year divided by the mass of liquid aluminium produced in the same year. | |
| The lower end of the range is associated with the use of a wet scrubber. The higher end of the range is associated with the use of low-sulphur anodes. | |
| Parameter | BAT-AEL (kg/t Al)f1 f2 |
|---|---|
| SO2 | ≤ 2,5-15 |
Annotations
Footnotes
- f1
-
As mass of pollutant emitted during a year divided by the mass of liquid aluminium produced in the same year.
- f2
-
The lower end of the range is associated with the use of a wet scrubber. The higher end of the range is associated with the use of low-sulphur anodes.
Notes on Division BAT 69
Footnotes
- f1
-
Description of the technique is given in Section 1.10.