Division Description
United Kingdom
BAT 84(d): Using chlorine diluted with inert gas instead of only pure chlorine, to reduce the emission of chlorine. Refining can also be performed using only the inert gas.
BAT-associated emission levels: See Table 19.
Table 19
BAT-associated emission levels for HCl, Cl2 and HF emissions to air from the thermal treatment of contaminated secondary raw materials (e.g. swarf), the melting furnace, and remelting and molten metal treatment
| As a daily average or as an average over the sampling period. For refining carried out with chemicals containing chlorine, the BAT-AEL refers to the average concentration during chlorination. | |
| As an average over the sampling period. For refining carried out with chemicals containing chlorine, the BAT-AEL refers to the average concentration during chlorination. | |
| Only applicable to emissions from refining processes carried out with chemicals containing chlorine. | |
| As an average over the sampling period. | |
| Parameter | BAT-AEL (mg/Nm3) |
|---|---|
| HCl | ≤ 5-10f1 |
| Cl2 | ≤ 1f2 f3 |
| HF | ≤ 1f4 |
Annotations
Footnotes
- f1
-
As a daily average or as an average over the sampling period. For refining carried out with chemicals containing chlorine, the BAT-AEL refers to the average concentration during chlorination.
- f2
-
As an average over the sampling period. For refining carried out with chemicals containing chlorine, the BAT-AEL refers to the average concentration during chlorination.
- f3
-
Only applicable to emissions from refining processes carried out with chemicals containing chlorine.
- f4
-
As an average over the sampling period.
Notes on Division BAT 84
Footnotes
- f1
-
Description of the techniques are given in Section 1.10.