# Commission Implementing Decision (EU) 2016/1032 of 13 June 2016 establishing best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council, for the non-ferrous metals industries (notified under document C(2016) 3563) (Text with EEA relevance), Division BAT 90

Extent: E+W+S+N.I.

In order to prevent or reduce diffuse emissions from preparation (such as metering, mixing, blending, crushing, cutting, screening) of primary and secondary materials (excluding batteries), BAT is to use one or a combination of the techniques given below.
Technique
Applicability
a
Enclosed conveyer or pneumatic transfer system for dusty material
Generally applicable
b
Enclosed equipment. When dusty materials are used the emissions are collected and sent to an abatement system
Only applicable for feed blends prepared with a dosing bin or loss-in-weight system
c
Mixing of raw materials carried out in an enclosed building
Only applicable for dusty materials. For existing plants, application may be difficult due to the space required
d
Dust suppression systems such as water sprays
Only applicable for mixing carried out outdoors
e
Pelletisation of raw materials
Applicable only when the process and the furnace can use pelletised raw materials

---