Division BAT 123
United Kingdom
In order to reduce emissions of organic compounds to air from the melting of metallic and mixed metallic/oxidic streams, and from the slag fuming furnace and the Waelz kiln, BAT is to use one or a combination of the techniques given below.
| Descriptions of the techniques are given in Section 1.10. | ||
| Techniquef1 | Applicability | |
|---|---|---|
| a | Injection of adsorbent (activated carbon or lignite coke) followed by a bag filter and/or ESP | Generally applicable |
| b | Thermal oxidiser | Generally applicable |
| c | Regenerative thermal oxidiser | May not be applicable due to safety reasons |
BAT-associated emission levels: See Table 35.
Table 35
BAT-associated emission levels for emissions to air of TVOC and PCDD/F from the melting of metallic and mixed metallic/oxidic streams, and from the slag fuming furnace and the Waelz kiln
| As a daily average or as an average over the sampling period. | ||
| As an average over a sampling period of at least six hours. | ||
| Parameter | Unit | BAT-AEL |
|---|---|---|
| TVOC | mg/Nm3 | 2-20f2 |
| PCDD/F | ng I-TEQ/Nm3 | ≤ 0,1f3 |
Annotations
Footnotes
- f1
-
Descriptions of the techniques are given in Section 1.10.
- f2
-
As a daily average or as an average over the sampling period.
- f3
-
As an average over a sampling period of at least six hours.