Division (A) Prior to the start of testing, the UUT shall be initialised as follows:
United Kingdom
- (1)
Set up the UUT as per the instructions in the supplied product manual.
- (2)
Connect an acceptable watt meter to the power source and connect the UUT to the power outlet on the watt meter.
- (3)
With the UUT off, set the ambient light level such that the measured screen illuminance is less than 1,0 lux (see Section 5.2(B)).
- (4)
Power on the UUT and perform initial system configuration, as applicable.
- (5)
Ensure UUT settings are in their as-shipped configuration, unless otherwise specified in this test method.
- (6)
Warm up the UUT for 20 minutes, or the time it takes the UUT to complete initialisation and become ready for use, whichever is longer. The IEC 62087:2011 test signal format, as specified in Section 5.2(G)(1), shall be displayed for the entire warm-up period. Displays that cannot display the IEC 62087:2011 test signal format shall have the VESA FPDM2 L80 test signal, as specified in Section 5.2(G)(2), displayed on the screen.
- (7)
Report the AC input voltage and frequency or DC input voltage.
- (8)
Report the test room ambient temperature and relative humidity.