  "url": "https://openlegislation.uk/eu-decision-2016-1756/annex-II/division-ANNEX/division-2/division-6/division-6.4",
  "json_url": "https://openlegislation.uk/eu-decision-2016-1756/annex-II/division-ANNEX/division-2/division-6/division-6.4.json",
  "legislation": "eudn/2016/1756",
  "legislation_title": "Commission Decision (EU) 2016/1756 of 28 September 2016 determining the European Union position with regard to a decision of the management entities under the Agreement between the Government of the United States of America and the European Union on the coordination of energy-efficiency labelling programmes for office equipment, on the revision of specifications for displays included in Annex C to the Agreement (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2016-1756",
  "path": "annex/II/division/ANNEX/division/2/division/6/division/6.4",
  "kind": "division",
  "number": "6.4",
  "heading": "On Mode testing for products with ABC enabled by default",
  "text": "The average On Mode power consumption of the product shall be determined with the dynamic broadcast-content as defined in IEC 62087:2011. If the product cannot display the IEC signal, then the VESA FPDM2 L80 test pattern, as described in Section 6.3(B)(5), shall be used for all of the following steps.\n(A) Stabilise the UUT for 30 minutes. This shall be done with three repetitions of the 10-minute IEC dynamic broadcast-content video signal.\n(B) Set the light output of the lamp used for testing to 12 lux as measured at the face of the ambient light sensor.\n(C) Display the 10 minute dynamic broadcast-content video signal. Measure and record the power consumption, P12, during the 10 minute dynamic broadcast-content video signal.\n(D) Repeat steps 6.4(B) and 6.4(C) for an ambient light level of 300 lux, to measure P300.\n(E) Disable ABC and measure On Mode power (PON) as per Section 6.3. If ABC cannot be disabled, power measurements shall be conducted as follows:\n(1) If the brightness can be set to a fixed value as specified in Section 6.3, then On Mode power for these products shall be measured as per Section 6.3 with light entering directly into the UUT's ambient light sensor at greater than or equal to 300 lux.\n(2) If the brightness cannot be set to a fixed value, then On Mode power for these products shall be measured as per Section 6.3 with light entering directly into the UUT's ambient light sensor at greater than or equal to 300 lux and without modifying the screen brightness.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2016/1756/annex/II/division/ANNEX/division/2/division/6/division/6.4",
    "retrieved_at": "2026-11-01T15:13:49.548511+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}