Division Equation 2 Total Energy Consumption Requirement for Monitors
United Kingdom
ETEC ≤ (ETEC_MAX + EEP + EABC + EN + EOS + ET ) × effAC_DC
Where:
-
ETEC is TEC in kWh calculated as per Equation 1,
-
ETEC_MAX is the Maximum TEC requirement in kWh calculated as per Table 1,
-
EEP is the enhanced performance display allowance in kWh as per Section 3.3.4,
-
EABC is the Automatic Brightness Control allowance in kWh as per Equation 4,
-
EN is the Full Network Connectivity allowance in kWh as per Table 3,
-
EOS is the Occupancy Sensor allowance in kWh as per Table 4,
-
ET is the Touch Technology allowance in kWh as per Equation 5, and
-
effAC_DC is the standard adjustment for AC-DC power conversion losses that occur at the device powering the Display, and is 1,0 for AC-powered Displays and 0,85 for Displays with Standard DC.