Division 3 MEASUREMENTS AND DETERMINATION OF THE PEAK POWER OUTPUT
United Kingdom
The measured average peak power output of the PV roof is to be determined experimentally for each vehicle variant. Initial stabilisation of the tested device is to be done in accordance with the methodology specified in the international standard IEC 61215-2:2016f1. The measurements of the peak power output shall be performed at standard test conditions as defined in the international standard IEC/TS 61836:2007f2.
A dismantled complete PV roof is to be used. The four corner points of the panel are to touch the measurement plane.
The measurements of the peak power output shall be performed at least five times and the arithmetic mean () has to be calculated.
Annotations
Footnotes
- f1
-
The International Electrotechnical Commission (IEC), IEC 61215-2:2016 standard for ‘Terrestrial photovoltaic (PV) modules — Design qualification and type approval’
- f2
-
The International Electrotechnical Commission (IEC), IEC 61836-2007 standard for ‘Solar photovoltaic energy systems — Terms, definitions and symbols’