Division 5 Paragraph 7 shall be deleted and replaced by the following text and footnote:
‘7.
The following limit values, which refer to 11 % O2 concentration in flue gas, apply to the following incinerator types:
Municipal solid waste (existing stationary source burning more than 3 tonnes per hour and every new stationary source)
0,1 ng TEQ/m3
Medical solid waste (existing stationary source burning more than 1 tonne per hour and every new stationary source)
New stationary source: 0,1 ng TEQ/m3 Existing stationary source: 0,5 ng TEQ/m3 Hazardous waste (existing stationary source burning more than 1 tonne per hour and every new stationary source)
New stationary source: 0,1 ng TEQ/m3 Existing stationary source: 0,2 ng TEQ/m3 Non-hazardous industrial wastef1 f2
New stationary source: 0,1 ng TEQ/m3 Existing stationary source: 0,5 ng TEQ/m3 ’
Annotations
Footnotes
- f1
-
Including incinerators treating biomass waste which may contain halogenated organic compounds or heavy metals as a result of treatment with wood- preservatives or coating, and which includes in particular biomass waste originating from construction and demolition waste, but excluding incinerators only treating other biomass waste.
- f2
-
Countries with economies in transition may exclude co-combustion of non-hazardous industrial waste in industrial processes where such waste is used as an additional fuel contributing up to 10 % of the energy,’