  "url": "https://openlegislation.uk/eu-decision-2017-1442/annex/division-3/division-3.3/division-3.3.1/division-1",
  "json_url": "https://openlegislation.uk/eu-decision-2017-1442/annex/division-3/division-3.3/division-3.3.1/division-1.json",
  "legislation": "eudn/2017/1442",
  "legislation_title": "Commission Implementing Decision (EU) 2017/1442 of 31 July 2017 establishing best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council, for large combustion plants (notified under document C(2017) 5225) (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2017-1442",
  "path": "annex/division/3/division/3.3/division/3.3.1/division/1",
  "kind": "division",
  "number": "BAT 36",
  "heading": "In order to increase the energy efficiency of gas oil combustion in gas turbines, BAT is to use an appropriate combination of the techniques given in BAT 12 and below.",
  "text": "Technique\nDescription\nApplicability\na.\nCombined cycle\nSee description in Section 8.2\nGenerally applicable to new units operated ≥ 1 500 h/yr.\nApplicable to existing units within the constraints associated with the steam cycle design and the space availability.\nNot applicable to existing units operated < 1 500 h/yr\nTable 21\nBAT-associated energy efficiency levels (BAT-AEELs) for gas-oil-fired gas turbines\nThese BAT-AEELs do not apply to units operated < 1 500 h/yr.\nNet electrical efficiency BAT-AEELs apply to CHP units whose design is oriented towards power generation, and to units generating only power.\nType of combustion unit\nBAT-AEELs\nNet electrical efficiency (%)\nNew unit\nExisting unit\nGas-oil-fired open-cycle gas turbine\n> 33\n25–35,7\nGas-oil-fired combined cycle gas turbine\n> 40\n33–44",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "These BAT-AEELs do not apply to units operated < 1 500 h/yr."
    },
    {
      "type": "footnote",
      "label": "f2",
      "text": "Net electrical efficiency BAT-AEELs apply to CHP units whose design is oriented towards power generation, and to units generating only power."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2017/1442/annex/division/3/division/3.3/division/3.3.1/division/1",
    "retrieved_at": "2026-11-01T15:13:23.628050+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}