# Commission Implementing Decision (EU) 2017/1442 of 31 July 2017 establishing best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council, for large combustion plants (notified under document C(2017) 5225) (Text with EEA relevance), Division 5.1.2: Energy efficiency

Extent: E+W+S+N.I.

Table 33
BAT-associated energy efficiency levels (BAT-AEELs) for the combustion of process fuels from the chemical industry in boilers
These BAT-AEELs do not apply to units operated < 1 500 h/yr.
In the case of CHP units, only one of the two BAT-AEELs ‘Net electrical efficiency’ or ‘Net total fuel utilisation’ applies, depending on the CHP unit design (i.e. either more oriented towards generation electricity or towards heat generation).
These BAT-AEELs may not be achievable if the potential heat demand is too low.
These BAT-AEELs do not apply to plants generating only electricity.
Type of combustion unit
BAT-AEELs
Net electrical efficiency (%)
Net total fuel utilisation (%)
New unit
Existing unit
New unit
Existing unit
Boiler using liquid process fuels from the chemical industry, including when mixed with HFO, gas oil and/or other liquid fuels
> 36,4
35,6–37,4
80–96
80–96
Boiler using gaseous process fuels from the chemical industry, including when mixed with natural gas and/or other gaseous fuels
39–42,5
38–40
78–95
78–95

---
Source: https://www.legislation.gov.uk/eudn/2017/1442/annex/division/5/division/5.1/division/5.1.2 (the official version)