# Commission Implementing Decision (EU) 2017/2117 of 21 November 2017 establishing best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council, for the production of large volume organic chemicals (notified under document C(2017) 7469) (Text with EEA relevance), Division BAT 57:: In order to reduce emissions of organic compounds to air, BAT is to use technique d given below for waste gas from the cumene oxidation unit. For any other individual or combined waste gas streams, BAT is to use one or a combination of the techniques given below.

Extent: E+W+S+N.I.

Technique
Description
Applicability
a.
Send the waste gas stream to a combustion unit
See BAT 9
Only applicable where there are available uses for the waste gas as gaseous fuel
b.
Adsorption
See Section 12.1
Generally applicable
c.
Thermal oxidiser
See Section 12.1
Generally applicable
d.
Regenerative thermal oxidiser (RTO)
See Section 12.1
Generally applicable
Table 7.1
BAT-AELs for emissions of TVOC and benzene to air from the production of phenol
Parameter
Source
BAT-AEL(daily average or average over the sampling period)(mg/Nm3, no correction for oxygen content)
Conditions
Benzene
Cumene oxidation unit
< 1
The BAT-AEL applies if the emission exceeds 1 g/h
TVOC
5–30
—
The associated monitoring is in BAT 2.

---