  "url": "https://openlegislation.uk/eu-decision-2017-2117/annex/division-n2/division-2",
  "json_url": "https://openlegislation.uk/eu-decision-2017-2117/annex/division-n2/division-2.json",
  "legislation": "eudn/2017/2117",
  "legislation_title": "Commission Implementing Decision (EU) 2017/2117 of 21 November 2017 establishing best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council, for the production of large volume organic chemicals (notified under document C(2017) 7469) (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2017-2117",
  "path": "annex/division/n2/division/2",
  "kind": "division",
  "number": null,
  "heading": "Averaging periods and reference conditions for emissions to air",
  "text": "Unless stated otherwise, the emission levels associated with the best available techniques (BAT-AELs) for emissions to air given in these BAT conclusions refer to values of concentration, expressed as mass of emitted substance per volume of waste gas under standard conditions (dry gas at a temperature of 273,15 K, and a pressure of 101,3 kPa), and expressed in the unit mg/Nm3.\nUnless stated otherwise, the averaging periods associated with the BAT-AELs for emissions to air are defined as follows.\nFor any parameter where, due to sampling or analytical limitations, 30-minute sampling is inappropriate, a suitable sampling period is employed.\nFor PCDD/F, a sampling period of 6 to 8 hours is used.\nType of measurement\nAveraging period\nDefinition\nContinuous\nDaily average\nAverage over a period of 1 day based on valid hourly or half-hourly averages\nPeriodic\nAverage over the sampling period\nAverage of three consecutive measurements of at least 30 minutes each\nWhere BAT-AELs refer to specific emission loads, expressed as load of emitted substance per unit of production output, the average specific emission loads ls are calculated using Equation 1:\nEquation 1:\nl s = 1 n ∑ i = 1 n c i q i p i\nwhere:\nn number of measurement periods;\nci average concentration of the substance during ith measurement period;\nqi average flow rate during ith measurement period;\npi production output during ith measurement period.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "For any parameter where, due to sampling or analytical limitations, 30-minute sampling is inappropriate, a suitable sampling period is employed."
    },
    {
      "type": "footnote",
      "label": "f2",
      "text": "For PCDD/F, a sampling period of 6 to 8 hours is used."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2017/2117/annex/division/n2/division/2",
    "retrieved_at": "2026-11-01T15:13:18.480772+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}