  "legislation_title": "Commission Implementing Decision (EU) 2017/302 of 15 February 2017 establishing best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council, for the intensive rearing of poultry or pigs (notified under document C(2017) 688) (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2017-302",
  "path": "annex/division/3/division/1/division/1.7/division/BAT+10",
  "kind": "division",
  "number": "BAT 10",
  "heading": null,
  "text": "In order to prevent, or where that is not practicable, to reduce noise emissions, BAT is to use one or a combination of the techniques given below.\nTechnique\nDescription\nApplicability\na\nEnsure adequate distances between the plant/farm and the sensitive receptors.\nAt the planning stage of the plant/farm, adequate distances between the plant/farm and the sensitive receptors are ensured by applying minimum standard distances.\nMay not be generally applicable to existing plants/farms.\nb\nEquipment location.\nNoise levels can be reduced by:\ni.. increasing the distance between the emitter and the receiver (by locating equipment as far away as practicable from sensitive receptors);\nii.. minimising the length of feed delivery pipes;\niii.. Locating feed bins and feed silos so as to minimise the movement of vehicles on the farm.\nIn the case of existing plants, the relocation of equipment may be restricted by the lack of space or excessive costs.\nc\nOperational measures.\nThese include measures, such as:\ni.. closure of doors and major openings of the building, especially during feeding time, if possible;\nii.. equipment operation by experienced staff;\niii.. avoidance of noisy activities at night and during weekends, if possible;\niv.. provisions for noise control during maintenance activities;\nv.. operate conveyers and augers full of feed, if possible;\nvi.. keep outdoor scraped areas to a minimum in order to reduce noise from scraper tractors.\nGenerally applicable.\nd\nLow-noise equipment.\nThis includes equipment, such as:\ni.. high efficiency fans, when natural ventilation is not possible or sufficient;\nii.. pumps and compressors;\niii.. feeding system which reduces the pre-feeding stimulus (e.g. holding hoppers, passive ad libitum feeders, compact feeders).\nBAT 7.d.iii is only applicable to pig plants.\nPassive ad libitum feeders are only applicable when the equipment is new or replaced or when animals do not require a restricted feeding.\ne\nNoise-control equipment.\nThis includes:\ni.. noise reducers;\nii.. vibration isolation;\niii.. enclosure of noisy equipment (e.g. mills, pneumatic conveyers);\niv.. soundproofing of buildings.\nApplicability may be restricted due to space requirements, and health and safety issues.\nNot applicable to noise-absorbent materials impeding the effective cleaning of the plant.\nf\nNoise abatement.\nNoise propagation can be reduced by inserting obstacles between emitters and receivers.\nMay not be generally applicable due to biosecurity reasons.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2017/302/annex/division/3/division/1/division/1.7/division/BAT+10",
    "retrieved_at": "2026-11-01T15:13:35.783160+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}