# Commission Implementing Decision (EU) 2018/1147 of 10 August 2018 establishing best available techniques (BAT) conclusions for waste treatment, under Directive 2010/75/EU of the European Parliament and of the Council (notified under document C(2018) 5070) (Text with EEA relevance), Division 1.8: Energy efficiency

Extent: E+W+S+N.I.

BAT 23. In order to use energy efficiently, BAT is to use both of the techniques given below.
Technique
Description
a.
Energy efficiency plan
An energy efficiency plan entails defining and calculating the specific energy consumption of the activity (or activities), setting key performance indicators on an annual basis (for example, specific energy consumption expressed in kWh/tonne of waste processed) and planning periodic improvement targets and related actions. The plan is adapted to the specificities of the waste treatment in terms of process(es) carried out, waste stream(s) treated, etc.
b.
Energy balance record
An energy balance record provides a breakdown of the energy consumption and generation (including exportation) by the type of source (i.e. electricity, gas, conventional liquid fuels, conventional solid fuels, and waste). This includes:
(i) information on energy consumption in terms of delivered energy;
(ii) information on energy exported from the installation;
(iii) energy flow information (e.g. Sankey diagrams or energy balances) showing how the energy is used throughout the process.
The energy balance record is adapted to the specificities of the waste treatment in terms of process(es) carried out, waste stream(s) treated, etc.

---