Division Description
United Kingdom
This includes all of the following measures:
-
equipment used to treat WEEE containing mercury is enclosed, under negative pressure and connected to a local exhaust ventilation (LEV) system;
-
waste gas from the processes is treated by dedusting techniques such as cyclones, fabric filters, and HEPA filters, followed by adsorption on activated carbon (see Section 6.1);
-
the efficiency of the waste gas treatment is monitored;
-
mercury levels in the treatment and storage areas are measured frequently (e.g. once every week) to detect potential mercury leaks.
Table 6.6
BAT-associated emission level (BAT-AEL) for channelled mercury emissions to air from the mechanical treatment of WEEE containing mercury
| Parameter | Unit | BAT-AEL(Average over the sampling period) |
|---|---|---|
| Mercury (Hg) | μg/Nm3 | 2-7 |
The associated monitoring is given in BAT 8.