  "legislation_title": "Commission Implementing Decision (EU) 2018/1147 of 10 August 2018 establishing best available techniques (BAT) conclusions for waste treatment, under Directive 2010/75/EU of the European Parliament and of the Council (notified under document C(2018) 5070) (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2018-1147",
  "path": "annex/division/4/division/4.6/division/4.6.2",
  "kind": "division",
  "number": "4.6.2",
  "heading": "Emissions to air",
  "text": "BAT 49. In order to reduce emissions of HCl, HF, dust and organic compounds to air, BAT is to apply BAT 14d and to use one or a combination of the techniques given below.\nThermal oxidation is carried out with a minimum temperature of 1 100 °C and a two-second residence time for the regeneration of activated carbon used in industrial applications where refractory halogenated or other thermally resistant substances are likely to be present. In the case of activated carbon used for potable water- and food-grade applications, an afterburner with a minimum heating temperature of 850 °C and a two-second residence time is sufficient (see Section 6.1).\nTechnique\nDescription\na.\nCyclone\nSee Section 6.1. The technique is used in combination with further abatement techniques.\nb.\nElectrostatic precipitator (ESP)\nSee Section 6.1.\nc.\nFabric filter\nd.\nWet scrubbing\ne.\nAdsorption\nf.\nCondensation\ng.\nThermal oxidation\nThe associated monitoring is given in BAT 8.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "Thermal oxidation is carried out with a minimum temperature of 1 100 °C and a two-second residence time for the regeneration of activated carbon used in industrial applications where refractory halogenated or other thermally resistant substances are likely to be present. In the case of activated carbon used for potable water- and food-grade applications, an afterburner with a minimum heating temperature of 850 °C and a two-second residence time is sufficient (see Section 6.1)."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2018/1147/annex/division/4/division/4.6/division/4.6.2",
    "retrieved_at": "2026-11-01T15:13:01.289264+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}