  "legislation_title": "Commission Implementing Decision (EU) 2018/1147 of 10 August 2018 establishing best available techniques (BAT) conclusions for waste treatment, under Directive 2010/75/EU of the European Parliament and of the Council (notified under document C(2018) 5070) (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2018-1147",
  "path": "annex/division/n3/division/2",
  "kind": "division",
  "number": null,
  "heading": "Emission levels associated with the best available techniques (BAT-AELs) for emissions to air",
  "text": "Unless stated otherwise, emission levels associated with the best available techniques (BAT-AELs) for emissions to air given in these BAT conclusions refer to concentrations (mass of emitted substances per volume of waste gas) under the following standard conditions: dry gas at a temperature of 273,15 K and a pressure of 101,3 kPa, without correction for oxygen content, and expressed in μg/Nm3 or mg/Nm3.\nFor averaging periods of BAT-AELs for emissions to air, the following definitions apply.\nFor any parameter where, due to sampling or analytical limitations, a 30-minute measurement is inappropriate, a more suitable measurement period may be employed (e.g. for the odour concentration). For PCDD/F or dioxin-like PCBs, one sampling period of 6 to 8 hours is used.\nType of measurement\nAveraging period\nDefinition\nContinuous\nDaily average\nAverage over a period of one day based on valid hourly or half-hourly averages.\nPeriodic\nAverage over the sampling period\nAverage value of three consecutive measurements of at least 30 minutes each.\nWhere continuous measurement is used, the BAT-AELs may be expressed as daily averages.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "For any parameter where, due to sampling or analytical limitations, a 30-minute measurement is inappropriate, a more suitable measurement period may be employed (e.g. for the odour concentration). For PCDD/F or dioxin-like PCBs, one sampling period of 6 to 8 hours is used."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2018/1147/annex/division/n3/division/2",
    "retrieved_at": "2026-11-01T15:13:01.289264+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}