OpenLegislation

Division Formula 1

United Kingdom

Original text. Later amendments are not shown.

η EI i = 60 × U i × I i 2π × M i × n i × 100

All efficiency measurements are to be performed consecutively at least five (5) times. The average of the measurements at each operating point ( η EI i – ) has to be calculated.

The efficiency of the eco-innovative alternator (ηEI) shall be calculated in accordance with Formula 2.