  "legislation_title": "Commission Implementing Decision (EU) 2019/2010 of 12 November 2019 establishing the best available techniques (BAT) conclusions, under Directive 2010/75/EU of the European Parliament and of the Council, for waste incineration (notified under document C(2019) 7987) (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2019-2010",
  "path": "annex/division/1/division/1.5/division/1.5.1",
  "kind": "division",
  "number": "1.5.1",
  "heading": "Diffuse emissions",
  "text": "BAT 21. In order to prevent or reduce diffuse emissions from the incineration plant, including odour emissions, BAT is to:\nstore solid and bulk pasty wastes that are odorous and/or prone to releasing volatile substances in enclosed buildings under controlled subatmospheric pressure and use the extracted air as combustion air for incineration or send it to another suitable abatement system in the case of a risk of explosion;\nstore liquid wastes in tanks under appropriate controlled pressure and duct the tank vents to the combustion air feed or to another suitable abatement system;\ncontrol the risk of odour during complete shutdown periods when no incineration capacity is available, e.g. by:\nsending the vented or extracted air to an alternative abatement system, e.g. a wet scrubber, a fixed adsorption bed;\nminimising the amount of waste in storage, e.g. by interrupting, reducing or transferring waste deliveries, as a part of waste stream management (see BAT 9);\nstoring waste in properly sealed bales.\nBAT 22. In order to prevent diffuse emissions of volatile compounds from the handling of gaseous and liquid wastes that are odorous and/or prone to releasing volatile substances at incineration plants, BAT is to introduce them into the furnace by direct feeding.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2019/2010/annex/division/1/division/1.5/division/1.5.1",
    "retrieved_at": "2026-11-01T15:12:29.772187+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}